MODEL
|
7305
|
GROUND BOND
|
Output AC Current
|
3~30A
|
Output AC Voltage
|
6V, Maximum
|
Output Frequerncy
|
50Hz/60Hz±100ppm, User Selection
|
SETTINGS
|
Max-Limit Range
|
Resistance
|
0~510mΩ
|
0~120mΩ
|
AC Current
|
3.0~10.0A
|
10.1~30.0A
|
Resolution
|
1mΩ
|
Accuracy
|
Same as Resistance Measurment Accuracy
|
Min-Limit Range
|
Resistance
|
-
|
AC Current
|
-
|
Resolution
|
1mΩ
|
Accuracy
|
Same as Resistance Measurment Accuracy
|
Lead Resistance Offset
|
Range
|
0~100mΩ, Auto/manual
|
Resolution
|
1mΩ
|
Accuracy
|
±(2% of setting +2 counts)
|
Dwell Time
|
Range
|
0, 0.5~999.9sec (0=continuous)
|
Resolution
|
0.1 sec
|
Accuracy
|
±(0.1% + 0.05sec)
|
MEASURMENT
|
AC Current
|
Range
|
3.0~30.0A
|
Resolution
|
0.1A
|
Accuracy
|
±(2%of reading +1count)
|
Resistance
|
Range
|
0~510mΩ
|
0~120mΩ
|
3.0~10.0A
|
10.1~30.0A
|
Resolution
|
1mΩ
|
Accuracy
|
±(2%of reading +1count)
|
GENERAL
|
Input Voltage AC
|
115/230Vac±15%, 50/60Hz ± 5%, Fuse 6.3A
|
PLC Remote Control
|
Output: Pass, Fail, Processing, Reset Out, Start Out
|
Memory
|
5 memories
|
Display
|
16×2 LCD with back light
|
Key Lock
|
To prevent unauthorized alteration of the test Parameters
|
Calibration
|
Build-in software and external calibrated meters
|
Environment
|
0-40℃, 20-80%RH
|
Dimension
|
280(W)×89(H)×370(D)mm
|
Net Weight
|
10kg
|
STANDARD ACCESSORIES
|
Power Cord(10A)
|
×1
|
Fuses
|
×2 (Includeing a spare contained in the fuse holder)
|
Ground Bond Reutrn Lead 30A, 1.6m(1122)
|
×1
|
Ground Bond Tester Lead 30A, 1.6m(1131)
|
×1
|
|
|
|
|